A Timer-Linked Zipper Door Retrofit for a Process Workshop
A surface-treatment materials workshop needed to replace a rapid door on a forklift route after repeated contact damaged the original brush-guided curtain. The replacement also needed to respond to an existing equipment timer. SEPPES supplied one 2,350 × 2,480 mm self-repairing zipper door and coordinated the timer interface alongside local operation from both sides.


- Opening
- 2,350 × 2,480 mm
- Door package
- One zipper rapid door
- Controls
- Timer and two-sided buttons
- 인계
- October 2026
The replacement had to fit the traffic and the process.
A frequent forklift route
The opening served materials movement within the workshop. Incidental contact had repeatedly displaced and damaged the old curtain. The team wanted a guide and curtain system that would be easier to restore after the types of contact the opening had experienced.
An existing equipment interface
The workshop needed the new door to interact with its installed timer. SEPPES treated the timer connection as a separate requirement from the local controls and agreed the interface before final operating checks.
Specify the guide system and the control interface separately.
| Design item | Project configuration | What to confirm at your site |
|---|---|---|
| Opening and door | One flexible zipper rapid door at a 2,350 × 2,480 mm opening, with a viewing strip and rear cover at the head. | Survey both jambs, the maximum load width and height, the guide protection and the space for servicing the head. |
| Curtain recovery | Zipper-style guides were selected to support curtain re-entry after eligible disengagement. | Confirm the recovery behavior of the selected door and the circumstances that require inspection or service. |
| Operating controls | Local push-button boxes on both sides and a relay interface for the process timer. | Identify which timer signals the door receives and how operators can request normal access. |
| On-site checks | The project record notes a timer-linked operating check before handover. | Agree the acceptance cases for the normal cycle, local control, protective inputs and timer faults before installation. |
Use the process signal to coordinate access.
Resolve the recurrent mechanical issue
A self-repairing guide arrangement gave the flexible curtain a way to return to its tracks after eligible disengagement. The selection addressed a recurring maintenance problem on an existing route. Forklift clearance, guide positioning and operator training still matter to the site’s everyday use.
Confirm the control boundaries
The team allowed for a relay connection from the workshop timer and checked its behavior with the new controller on site. On a similar retrofit, identify the equipment issuing the request and agree how timer requests, manual controls and protective devices interact. The exact sequence should follow the site's approved control design.


Check the door by itself, then with the equipment timer.
Survey and specification
SEPPES reviewed the opening and the old door’s contact history, then defined the zipper configuration, cover and local controls.
Fit and connect
The team installed the new door and coordinated the relay interface with the workshop equipment team.
인계
The project record lists on-site timer-linked testing and handover in October 2026.
What the project delivered
The existing process opening gained a flexible zipper door with a timer-linked control interface. The project illustrates how a retrofit can address physical curtain damage and the requirements of an existing control system in one coordinated door package.
What to include in an enquiry
Describe how the old door is damaged
Share the direction of travel, the largest loads, photos of the guide and notes about the contact that usually causes the problem. Include the available clearances and whether the route can be temporarily diverted.
Bring the equipment interface to the review
Share the timer output type and desired behavior, then agree the conditions for manual operation and protective responses with the door and equipment teams.
Questions about this configuration
Why select a zipper door for this retrofit?
The original guide system had recurring curtain damage after contact on a forklift route. The zipper guides were selected to support re-entry of the flexible curtain after eligible disengagement.
Can a retrofit door use an existing timer?
The door and the timer can be coordinated when the two controllers have compatible signals and the desired behavior is specified. This project used a relay interface and checked operation with the installed equipment.
Can local push buttons still be available?
The project included local operation from both sides. The agreed control design should define when those buttons can request door movement and how the system handles concurrent requests.
What belongs in an acceptance check?
Include complete door travel, local controls, the normal timer command, protective-device response and recovery after a fault or stoppage. The authorised project team should agree and record the checks for the actual installation.
Share the passage dimensions and timer interface.
Send a marked layout, opening dimensions, site photographs and your main operating requirement. SEPPES can review the door, mounting conditions and equipment interfaces with your project team.